Answers to some questions about Bonve Rotary Lobe Pump

2025/02/06
Article from:Bonve Marketing/Bonve Marketing
Readership:274 order

A: What is the problem that the pump is stuck during operation?

Q:It is caused by the pipeline not being cleaned and leaving welding slag.

 

A:What is the problem that the pump trips as soon as it is started?

Q:It is caused by the material drying in the pump.

 

A:What is the situation that the pump can't suck out the material?

Q:It is a problem with the seal of the inlet pipe.

 

A: What is the problem that the outlet and the pump body sometimes vibrate?

Q:It is caused by the outlet pipe is not fixed and the pump speed is too high.

 

A: What should I do if the machine seal leaks and causes material to enter the gear box?

Q:Install stopper between machine seal and skeleton oil seal.

 

A: Skeleton oil seal of gear box will leak oil.

Q: There is a problem during the installation of the oil seal.

 

......

 